ConductCognition
  • Domains

    Tests

    • Processing speed55
    • Attention143
    • Working memory51
    • Executive function191
    • Episodic memory84
    • Response inhibition10
    • Social cognition97
    • Language50

    Most used

    Evidence

    1. Verbal Fluency TestGradeA
    2. Stroop Color-Word TestGradeA
    3. Trail Making TestGradeA
    4. N-Back TaskGradeA
    5. Go/No-Go TaskGradeA
    6. Digit Span TestGradeA
    7. Symbol Coding TestGradeA
    8. Verbal Learning TestGradeA
    REDTry it nowStroop Color-Word Test
    All 681 tests

    Browse by

    • Phone380
    • Tablet415
    • Untimed419
    • Up to 5 minutes81
    • Evidence grade A48
  • First studies

    Grade, length

    • Reaction Time StudyGradeA7 min
    • Pilot ScreeningGradeA15 min
    • Medication StudiesGradeA−26 min
    • Language-Minimized ScreeningGradeA−30 min

    Age groups

    • Older Adult Executive SpeedGradeA20 min
    • School-AgeGradeA−33 min

    Memory

    • At-Home MemoryGradeA26 min
    • Working Memory and LearningGradeA−19 min
    • Associative MemoryGradeB32 min
    • Working Memory CapacityGradeB34 min

    Language and perception

    • LanguageGradeA−33 min
    • Visual PerceptionGradeB27 min
    • Listening and Auditory ProcessingGradeB31 min

    Executive function and attention

    • Executive ControlGradeA18 min
    • Attention and ImpulsivityGradeA−26 min
    • Visual AttentionGradeB27 min
    • Creativity and Flexible ThinkingGradeB30 min
    • Reasoning and SpatialGradeB32 min

    Movement

    • Motor and AttentionGradeA−29 min
    • Motor LearningGradeB34 min

    Behavior, mood and choice

    • Food Choice and Self-ControlGradeA−29 min
    • Sleep and FatigueGradeB23 min
    • Social CognitionGradeB23 min
    • Impulsivity and Substance UseGradeB26 min
    • Emotion and MoodGradeB28 min
    • Decisions and RewardGradeB29 min
    All 26 batteries

    Find one

    Up to 15 minutes2Up to 30 minutes19Phone8
    Test order labBattery gradesHow batteries work
  • Use and evidence

    • Overview
    • Compare all 681 tests
    • Test-retest
    • Reliability and validity
    • Battery grades26
    • Download and cite

    Clinical trials

    • Overview
    • By condition25
    • By test103
    • Trial design benchmark
    • Cognitive outcomes, 2026

    Conditions

    Registered studies

    • Dementia and Alzheimer's1,673
    • Aging, frailty and exercise1,400
    • Depression and bipolar disorder1,249
    • Stroke1,237
    • Substance use and addiction904
    • Parkinson's disease894
    • Cancer762
    All 25 conditions
    16,526Registered studies name a cognitive test in an outcome measure11,848 name a test you can run hereExplore the studies
  • 1

    Build

    • Study design
    • Customize tests
    • Repeat visits
    • Study cost calculator
    2

    Recruit

    • Recruitment setup
    • Prolific
    • Sona Systems
    • CloudResearch Connect
    • Qualtrics
    3

    Run

    • Remote testing
    • Participant devices
    • Phone timing check
    • Offline edition
    4

    Results

    • Automated scoring
    • Test norms
    • Study Quality Monitor
    • Data export
    Platform overview

    Compliance

    • HIPAA-ready testing
    • US clinical research
    • Data Policy
    • Privacy Policy
    • Terms of Use
  • Research areas

    Tests used in each

    • Aging and dementia202
    • Decisions and reward136
    • Child development and education114
    • Social behavior87
    • Language and bilingualism80
    • Psychiatric groups35
    • Training and intervention31
    • Mood, anxiety and trauma28
    • Substance use and impulsivity26
    • Neurological and movement research21
    • Sleep and fatigue17
    • Brain injury and concussion14
    • ADHD11
    • Eating and obesity11
    • Medication and drug trials8

    Research settings

    • Student participant pools
    • Teaching a class
    • Clinical trials
    • US clinical research
    • Sites without internet
    Planning a study?
  • Methods

    • How evidence grades work
    • How test batteries work
    • How test order works
    Methods and questions

    Help

    • FAQ
    • Recruitment guides
    • Compare platforms

    Updates

    • Blog
    • New tests by email
    Latest post10 November 2026What you can do in ConductCognition todayA short tour of ConductCognition as it stands on 10 November. After this, we'll post when something changes how you run a study.Read the post
  • Pricing
Start Free
Log In
Log InStart Free
  1. Home
  2. /Tests
  3. /Self-Made Sounds Task

Processing Speed

Self-Made Sounds Task

Also called: sensory attenuation task, self-generated sounds task, self-generated tones, attenuation of self-generated sounds, loudness of self-produced tones, action effect loudness comparison

Measure whether a tone you start sounds quieter than the same tone the computer starts: participants press a key, or watch the computer press it, to start a tone, then say which of two tones through headphones was louder.

10-12 minTimed: desktop or laptop with a mouse or trackpad

Create a study with this test

Free to start: 10 free participants per account, then $0.99 per participant for academic research, or any yearly plan. Try it here first, with no account.

Papers, 2021 to 2025
188
Evidence grade
C
Registered clinical studies
4
How these are counted
SPACE
You press, or the computer does
Listen through headphonesTwo short tones
Which tone was louder?
FirstSecond
Loudness match compared
Press the space bar, or watch the computer press it, to start a tone, then say which of two tones was louder
  • Overview
  • Evidence
  • Task design
  • Quality checks
  • Settings
  • Cite
  • Questions

What it measures

Measures whether a tone you start sounds quieter than the same tone the computer starts. Participants press the space bar, or watch the computer press it, to start a tone a fixed delay later, then say which of two tones over headphones was louder. The main score is the shift in the loudness match between the two. Needs headphones and normal hearing; results are research measures, not a hearing test.

Constructs

  • Sensory attenuation
  • Action-effect prediction
  • Loudness perception
  • Self-generated sounds

Research uses

  • Action and perception research
  • Auditory perception research
  • Within-study group comparison

How the paradigm works

Sounds people make themselves are heard as quieter than the same sounds made by something else, a result called sensory attenuation. It was first described for touch (Blakemore, Wolpert and Frith, 1998) and has been studied for sound with loudness comparisons, brain recordings and force matching; the reviews of Hughes, Desantis and Waszak (2013) and Kiepe, Kraus and Hesselmann (2021) set out the evidence and where it is mixed. This task measures it as Weiss, Herwig and Schütz-Bosbach (2011) did: a key press starts a first tone, a second tone follows, and the listener says which of the two was louder. The second tone takes five levels around the first, so the answers give the level at which the two tones sound equally loud, the loudness match, and the score is the shift in that match between the tones the participant started and the tones the computer started.

More about the paradigm

Set a comfortable volume and complete the 6-trial headphone check. A failed check stops the task by default; researchers can choose to continue with a quality flag.

Each trial plays two 1 kHz tones of 100 ms, the second 800 to 1,200 ms after the first ends. The first is always the standard, 4 dB below the volume-setting tone; the second is the standard plus -3, -1.5, 0, 1.5 or 3 dB. In a self part the participant presses the space bar when a drawn key lights. In a computer part the key sinks by itself, after a wait taken from one of the participant's own earlier presses, so the tone arrives at a time the participant could expect, as after their own press: Kaiser and Schütz-Bosbach (2018) found in the brain's response that self-made sounds were weaker than other sounds only when the onset of the other sounds could not be predicted, and that a cue to their onset reversed the difference. In both, the first tone is heard a fixed delay after the key, 100 ms as standard (250 or 500 ms as a setting). The tone is placed on the audio clock so that the device's own report says when it is heard, and the delay as played is saved with every trial. Choose First or Second with a click or the 1 and 2 keys, with no time limit.

Four parts, self, computer, computer, self or the reverse, in an order drawn from the session's seed, each holding every level 5 times (3 to 7 as a setting): 100 trials, after 4 practice trials with the second tone 4 dB louder or quieter, with feedback. A self trial with no press in 10 seconds is a missed press.

For each kind of part, a logistic function is fitted by maximum likelihood to the share of "second louder" answers at each level, as Weiss and colleagues did; its 50 percent point is the loudness match, in dB relative to the first tone. The primary score is the match for the computer's tones minus the match for the participant's own tones: above 0 when the first tone sounded quieter after the participant's own press. The step above each match for 75 percent, the share of "first louder" answers in each kind of part, the delay as played, late tones and answer times come with it. Reznik, Henkin, Levy and Mukamel (2015) found the effect for tones of 75 dB SPL and the opposite for tones just above threshold, so the first tone sits well above threshold and the scores describe tones at that level.

Scores

AttenuationdB
The loudness match for the computer's tones minus the match for the participant's own tones, each the level of the second tone, relative to the first, at which both sound equally loud.
Above 0 when the first tone sounded quieter after the participant's own press; no better direction
Loudness Match, Own TonesdB
The second tone's level relative to the first at which both sound equally loud when the participant started the first tone: the 50 percent point of a logistic function of the answers.
Below 0 means the first tone sounded quieter than a second tone at the same level
Loudness Match, Computer's TonesdB
The same match when the computer started the first tone.
Below 0 means the first tone sounded quieter than a second tone at the same level
Step to 75 Percent, Own TonesdB
How far above the match the second tone must be for "second louder" to be chosen 75 percent of the time, when the participant started the first tone.
Smaller means louder and quieter tones were told apart more finely
Step to 75 Percent, Computer's TonesdB
The same step when the computer started the first tone.
Smaller means louder and quieter tones were told apart more finely
First Tone Louder, Own Tones%
Share of answers that chose the first tone as louder in the parts where the participant started it.
Lower than for the computer's tones when the first tone sounded quieter after the participant's press
First Tone Louder, Computer's Tones%
Share of answers that chose the first tone as louder in the parts where the computer started it.
Informational; the levels are balanced around the first tone
Planned Delayms
The delay from the key to the first tone as planned: 100, 250 or 500 ms.
Informational
Delay as Playedms
Median delay from the key press to the first tone as played, by the device's report, in the parts where the participant pressed.
Should match the planned delay
Late Tonescount
First tones heard more than 20 ms after the planned delay.
More than max(3, 10%) of the trials is flagged for review
Missed Pressescount
Self trials with no press within 10 seconds, which have no answer.
More than max(3, 25%) of the trials makes the session invalid; any is flagged
Ignored Pressescount
Presses that did not start a tone: before the key lit, during a computer trial or after the first tone.
Informational
Median Answer Timems
Median time from when the answers opened, after the second tone, to the answer.
Informational; the answer has no time limit
Anticipationscount
Answers within 100 ms of the answers opening, which leave every score.
Half or more of the answers makes the session invalid
Completed Trialstrials
Trials answered in the scored run.
Fewer than planned is flagged for review
Planned Trialstrials
Trials the run set out to play.
Informational
Headphone Check Passed0/1
1 when the headphone check passed (at least 5 of 6 right), 0 when it did not.
0 stops the test unless the study set it to continue
Headphone Check Correctcount
Headphone check trials answered right, of 6.
5 or 6 passes
Reported Output Delayms
Output delay the device reported to the browser; empty when the browser does not report it.
Informational

Use and evidence

188 papers from 2021 to 2025 name this task in their title or abstract, up 59% compared with 2016 to 2020. That ranks it 179 of 711 test families in our census. See the counts for every test.

2021 to 2025, the years gradedEarlier years
Papers per year naming the Self-Made Sounds Task, 2000 to 2025Bar chart. 2021: 37; 2022: 30; 2023: 28; 2024: 33; 2025: 60 papers. Peak year 2025.02040602000: 1 papers2001: 2 papers2002: 2 papers2003: 3 papers2004: 0 papers2005: 4 papers2006: 1 papers2007: 5 papers2008: 4 papers2009: 3 papers2010: 8 papers2011: 13 papers2012: 14 papers2013: 21 papers2014: 22 papers2015: 24 papers2016: 22 papers2017: 27 papers2018: 27 papers2019: 26 papers2020: 16 papers2021: 37 papers2022: 30 papers2023: 28 papers2024: 33 papers2025: 60 papers200020052010201520202025
Papers per year naming the Self-Made Sounds Task, 2000 to 2025Bar chart. 2021: 37; 2022: 30; 2023: 28; 2024: 33; 2025: 60 papers. Peak year 2025.02040602000: 1 papers2001: 2 papers2002: 2 papers2003: 3 papers2004: 0 papers2005: 4 papers2006: 1 papers2007: 5 papers2008: 4 papers2009: 3 papers2010: 8 papers2011: 13 papers2012: 14 papers2013: 21 papers2014: 22 papers2015: 24 papers2016: 22 papers2017: 27 papers2018: 27 papers2019: 26 papers2020: 16 papers2021: 37 papers2022: 30 papers2023: 28 papers2024: 33 papers2025: 60 papers200020052010201520202025
Papers per year whose title or abstract names this task (OpenAlex).
Show the numbers
YearPapers
202560
202433
202328
202230
202137
202016
201926
201827
201727
201622
201524
201422
201321
201214
201113
20108
20093
20084
20075
20061
20054
20040
20033
20022
20012
20001
C

Use grade C

100 to 299 papers from 2021 to 2025.

C

Evidence grade C

At least 2 test-retest papers, 30 reliability or validity papers or 3 registered clinical studies.

Papers on test-retest reliability
0
Papers on reliability or validity
22
Registered clinical studies using it as an outcome
4

Measured on ConductCognition

Pooled across the studies that feed our platform norms, by device group. A figure needs 50 or more people.

No pooled figure yet.

Note on the counts: includes brain-recording and force-matching studies.

How the grades work

Use: A is 1,000 or more papers from 2021 to 2025, B 300 to 999, C 100 to 299, D 30 to 99 and E fewer than 30. Evidence: A means at least 25 papers report its test-retest reliability and at least 25 registered clinical studies use it as an outcome; B, at least 8 test-retest papers, and either 5 registered clinical studies or 150 reliability or validity papers; C, at least 2 test-retest papers, 30 reliability or validity papers or 3 registered clinical studies; D, little published measurement evidence found. The counts measure use. They include every paper that names the task in its title or abstract. Grades describe the published research on this task, not ConductCognition's version of it.

Source: ConductCognition test census 0.58.0, counted 16 November 2026 from OpenAlex and ClinicalTrials.gov.

Task design

The trial sequence as the test runs in ConductCognition.

Sound setup
The participant turns the device's volume until a steady 1 kHz tone is comfortable, then takes a 6-trial headphone check (Woods and colleagues, 2017). By default a failed check ends the test; its result is saved either way.
Trial
Two 1 kHz tones of 100 ms, the second 800 to 1,200 ms after the first ends. The first tone is always the standard, 4 dB below the volume-setting tone. The second is the standard plus -3, -1.5, 0, 1.5 or 3 dB. Choose First or Second for the louder tone, with a click or the 1 and 2 keys and no time limit.
Who starts the first tone
In a self part the participant presses the space bar when a drawn key lights. In a computer part the key sinks by itself, after a wait taken from one of the participant's own earlier presses, so the tone comes at a time the participant could expect, as after their own press.
Delay
The first tone is heard 100 ms after the key (250 or 500 ms as a setting) in both kinds of part. It is placed on the audio clock, so the device's report says when it is heard, and the delay as played is saved with every trial.
Parts
Four, self, computer, computer, self or the reverse, in an order drawn from the session's seed. Each holds every level 5 times (standard, 3 to 7): 100 trials, after 4 practice trials with the second tone 4 dB louder or quieter and feedback for 1,500 ms.
Score
For each kind of part, a logistic function fitted to the share of "second louder" answers at each level gives the loudness match, the level of the second tone at which both sound equally loud. The main score is the match for the computer's tones minus the match for the participant's own, in dB. The step above each match for 75 percent, the share of "first louder" answers, the delay as played and the answer times come with it. Answers under 100 ms leave every score.

Both tones of a trial play through the participant's own headphones at a volume they chose, so the score compares one tone with the other and no sound level is claimed. The delay between key and tone is held fixed and saved with the time it was played; first tones heard more than 20 ms late are counted, and a session in which more than a tenth were late is flagged. A session in which the answers did not follow the second tone's level, or most self trials had no press, is flagged or invalid. The score is a shift in loudness between two kinds of tone: it makes no claim about agency or about any disorder, and it is not a hearing test. The test needs normal hearing, a physical keyboard and headphones, wired if possible: wireless headphones play sound late. No percentile is given.

Quality checks

Each session is marked valid, needs review or invalid, with the reason, before you see its scores.

Scored rows: self_made_sounds_trial from the selected run: two tones, then First or Second for the louder, with no time limit, graded from the saved button and the second tone's level (the trials with the two tones equal have no right answer). Below chance (one half) invalidates and not above chance is flagged; one button on 90% of answers invalidates when accuracy is not above chance; a self trial with no press within 10 seconds is a missed press, and more than max(3, 25%) of them invalidate; answers under 100 ms invalidate when at least half. A headphone check that stopped the test invalidates; a failed check with the test run anyway, a part with no loudness match, first tones heard late on more than max(3, 10%) of trials and a run short of its planned trials are flagged for review.

Why these rules

Accuracy significantly below chance (one-sided exact test, p < .05) cannot come from guessing; it means the response mapping was reversed or the task was not followed (Slick, Sherman and Iverson 1999 treat below-chance forced-choice performance as definite response bias). Chance-level accuracy can be a real result in impaired participants, so it is only flagged. One option on at least 90% of answered trials, when the correct options are balanced and accuracy is not above chance, means the answers did not depend on the items (the task counterpart of long-string responding in surveys; Curran 2016). The second tone is 1.5 or 3 dB above or below the standard on four of every five trials, so a listener who hears the tones answers them well above chance. The answers open once both tones have played, so an answer under 100 ms was pressed before they opened. A key press that never comes means the participant did not take part. The first tone is placed on the audio clock at a fixed delay after the press, so tones the device played late are flagged. Woods, Siegel, Traer and McDermott (2017) let only listeners who passed the headphone check go on, because a listener on loudspeakers hears the sounds differently; a session that ran after a failed check keeps its scores but not its percentile.

No percentile. Scores and quality flags only.

Running this test

Settings you can change

SettingStandardAllowed
Trials of each level in each part53 to 7
Delay from key to first tone100 ms (standard)100 ms (standard), 250 ms, 500 ms
When the headphone check failsStop the testStop the test, Continue the test

Yearly plans can change settings within these limits. Free and pay-as-you-go studies use the standard settings.

How test settings work

Need a setting this test does not have?

Devices and languages

  • Timed test: participants need a desktop or laptop with a mouse or trackpad. Needs headphones. Participant devices
  • Languages: English, Spanish, French, German, Italian, Portuguese (Brazil), Chinese (Simplified) and Japanese.
  • Available on: Every plan, including the free plan.
  • No percentile. Scores and quality flags only. How norms work
  • Recruiting online? See the setup guides for Prolific, Sona Systems, CloudResearch Connect and Qualtrics.

Cite and describe

Methods text, with the standard settings

Participants completed the Self-Made Sounds Task in a web browser (ConductCognition task version 1.0.0, scoring version 1.0.0; Weiss, Herwig and Schütz-Bosbach, 2011; Blakemore, Wolpert and Frith, 1998; Hughes, Desantis and Waszak, 2013), with the standard settings (trials of each level in each part: 5; delay from key to first tone: 100 ms; when the headphone check fails: Stop the test). The main score was attenuation (the loudness match for the computer's tones minus the match for the participant's own tones, each the level of the second tone, relative to the first, at which both sound equally loud).

ConductCognition versions: task version 1.0.0, scoring version 1.0.0. Every export records the versions each session used, for a methods section.

  • Weiss, C., Herwig, A., & Schütz-Bosbach, S. (2011). The self in social interactions: Sensory attenuation of auditory action effects is stronger in interactions with others. PLoS ONE, 6(7), e22723. https://doi.org/10.1371/journal.pone.0022723The method: a tone a set time after a key press, a second tone, which was louder, and a logistic fit for the loudness match.
  • Reznik, D., Henkin, Y., Levy, O., & Mukamel, R. (2015). Perceived loudness of self-generated sounds is differentially modified by expected sound intensity. PLOS ONE, 10(5), e0127651. https://doi.org/10.1371/journal.pone.0127651Tones started by a key press and by a computer compared, with the effect depending on the tone's level.
  • Hughes, G., Desantis, A., & Waszak, F. (2013). Mechanisms of intentional binding and sensory attenuation: The role of temporal prediction, temporal control, identity prediction, and motor prediction. Psychological Bulletin, 139(1), 133-151. https://doi.org/10.1037/a0028566A review of sensory attenuation and what it depends on.
  • Kaiser, J., & Schütz-Bosbach, S. (2018). Sensory attenuation of self-produced signals does not rely on self-specific motor predictions. European Journal of Neuroscience, 47(11), 1303-1310. https://doi.org/10.1111/ejn.13931Why the computer's key sinks before its tone, so that its onset can be expected.
  • Kiepe, F., Kraus, N., & Hesselmann, G. (2021). Sensory attenuation in the auditory modality as a window into predictive processing. Frontiers in Human Neuroscience, 15, 704668. https://doi.org/10.3389/fnhum.2021.704668A review of the paradigms for sounds and where their results are mixed.
  • Blakemore, S.-J., Wolpert, D. M., & Frith, C. D. (1998). Central cancellation of self-produced tickle sensation. Nature Neuroscience, 1(7), 635-640. https://doi.org/10.1038/2870The first report of the effect, for touch.
  • Woods, K. J. P., Siegel, M. H., Traer, J., & McDermott, J. H. (2017). Headphone screening to facilitate web-based auditory experiments. Attention, Perception, & Psychophysics, 79(7), 2064-2072. https://doi.org/10.3758/s13414-017-1361-2The headphone check before the test.

Source papers

  • Weiss, Herwig and Schütz-Bosbach (2011): the loudness match from a logistic function of the answers, for tones started by the participant's own press and by another person's, in 40 adults. Reznik, Henkin, Levy and Mukamel (2015): the share of first tones judged louder, for tones started by a key press and by a computer, in 28 adults.Paradigm source, Adults

Questions

How long does the Self-Made Sounds Task take?

About 10 to 12 minutes, as listed in the test library.

What device does a participant need?

Timed test: participants need a desktop or laptop with a mouse or trackpad. Needs headphones. The browser must be Chrome, Edge, Firefox or Safari.

What scores does it produce?

Attenuation, Loudness Match, Own Tones, Loudness Match, Computer's Tones, Step to 75 Percent, Own Tones, Step to 75 Percent, Computer's Tones, First Tone Louder, Own Tones, First Tone Louder, Computer's Tones, Planned Delay, Delay as Played, Late Tones, Missed Presses, Ignored Presses, Median Answer Time, Anticipations, Completed Trials, Planned Trials, Headphone Check Passed, Headphone Check Correct and Reported Output Delay. Each session is also marked valid, needs review or invalid, with the reason.

How widely is the Self-Made Sounds Task used in research?

188 papers from 2021 to 2025 name it in their title or abstract, up 59% compared with 2016 to 2020. That ranks it 179 of 711 test families in the ConductCognition test census (use grade C). Source: ConductCognition test census 0.58.0, counted 16 November 2026 from OpenAlex and ClinicalTrials.gov.

How much reliability evidence does the Self-Made Sounds Task have?

In the published research, 0 papers report its test-retest reliability and 4 registered clinical studies use it as an outcome (evidence grade C in the ConductCognition test census).

Does it report a percentile?

No. Scores and quality flags only.

Which settings can a researcher change?

Trials of each level in each part (3 to 7), delay from key to first tone (100 ms (standard), 250 ms, 500 ms) and when the headphone check fails (Stop the test, Continue the test). Settings can be changed on yearly plans; free and pay-as-you-go studies use the standard settings.

Which languages can participants use?

Participants can take this test in English, Spanish, French, German, Italian, Portuguese (Brazil), Chinese (Simplified) and Japanese. English is on every plan, and the other languages come with yearly plans. Have a native speaker read the machine-translated text before launch.

Is this a clinical test?

No. ConductCognition is for research use only. It runs, scores and exports the test; clinical interpretation is outside the platform.

Every test: the full test list.

New tests and features, about once a month. Unsubscribe at any time.

Run this test in your next study

Start free with 10 free participants on any test, then use participant credits or a yearly plan.

Start free

Related tests

Intentional Binding TaskAgency Judgments TaskBeat Tapping Task
ConductCognition

Hosted browser-native cognitive testing for academic and commercial research workflows.

A product of ConductScience, Inc.

Tests

  • All cognitive tests
  • Test batteries
  • Use and evidence
  • Test norms
  • Trail Making Test
  • N-Back Task
  • Big Five personality test
  • Automated scoring
  • Study design
  • New tests by email

Guides

  • Methods and questions
  • Blog
  • Recruitment setup
  • Participant devices
  • Prolific
  • Sona Systems
  • CloudResearch Connect
  • Qualtrics

Use cases

  • Student participant pools
  • Aging and dementia research
  • Clinical trials
  • US clinical research
  • Remote testing

Compare and buy

  • Pricing
  • Compare platforms
  • Offline edition
  • FAQ

Trust

  • Study Quality Monitor
  • HIPAA-ready testing
  • Data export
  • Privacy Policy
  • Terms of Use
  • Data Policy

Company

  • ConductScience
  • ConductScience Fellows
© 2026 ConductScience, Inc. Research use only.