Attention
Self-Motion Task
Also called: vection, illusory self-motion, visually induced self-motion, linear vection, circular vection, roll vection, optic flow, self-motion perception
Measure vection, the feeling of moving that full-screen moving dots give a person sitting still: the time to the feeling and its strength by flow and speed.
8-10 minTimed: desktop or laptop with a mouse or trackpad
Free to start: 10 free participants per account, then $0.99 per participant for academic research, or any yearly plan. Try it here first, with no account.
- Papers, 2021 to 2025
- 87
- Evidence grade
- C
- Registered clinical studies
- 4
What it measures
Measures vection, the feeling of moving that a moving scene gives a person who sits still. A field of dots fills the screen and flows outward or turns, at a slow or a fast speed, for 30 s, with still dots as a control. Participants press the space bar when they feel they are moving, then rate how strongly. Scores the time to that press and the strength of the feeling by flow and speed.
Constructs
- Vection
- Visual self-motion perception
- Optic-flow processing
Research uses
- Research on visual motion and self-motion perception
- Virtual reality and simulator research
- Individual differences in visually induced self-motion
Scores
- Strength of Self-Motionpoints
- Mean rating of how strongly the participant felt they were moving, 1 (not at all) to 7 (very strongly), over the moving displays shown to the end.
- Higher means a stronger feeling of moving; neither end is better
- Time to Self-Motionseconds
- Median time from the start of motion to the first press of the space bar, over moving displays with a press; presses within 100 ms of the start leave it.
- Lower means the feeling of moving came sooner
- Displays with Self-Motion%
- Share of the moving displays shown to the end with a press of the space bar after the first 100 ms.
- Higher means the feeling of moving came more often
- Strength, Slow Expanding Flowpoints
- Mean rating for expanding flow at the slow speed, 2 depth units per second.
- Higher means a stronger feeling of moving
- Strength, Fast Expanding Flowpoints
- Mean rating for expanding flow at the fast speed, 5 depth units per second.
- Higher means a stronger feeling of moving
- Strength, Slow Rotating Flowpoints
- Mean rating for rotating flow at the slow speed, 25 degrees per second.
- Higher means a stronger feeling of moving
- Strength, Fast Rotating Flowpoints
- Mean rating for rotating flow at the fast speed, 50 degrees per second.
- Higher means a stronger feeling of moving
- Time to Self-Motion, Slow Expanding Flowseconds
- Median time to the first press for expanding flow at the slow speed.
- Lower means sooner
- Time to Self-Motion, Fast Expanding Flowseconds
- Median time to the first press for expanding flow at the fast speed.
- Lower means sooner
- Time to Self-Motion, Slow Rotating Flowseconds
- Median time to the first press for rotating flow at the slow speed.
- Lower means sooner
- Time to Self-Motion, Fast Rotating Flowseconds
- Median time to the first press for rotating flow at the fast speed.
- Lower means sooner
- Strength, Still Dotspoints
- Mean rating for the still dots, the control.
- A baseline for the moving displays
- Presses for Still Dots%
- Share of the still-dot displays with a press after the first 100 ms.
- A baseline for the moving displays
- Early Pressescount
- Presses of the space bar in the still second before motion began, which are not taken as reports.
- Informational
- Anticipationscount
- First presses within 100 ms of the start of motion, which leave the times.
- More than max(2, 20%) is invalid
- Frame Intervalms
- Median time between screen frames during the displays.
- About 16.7 on a 60 Hz screen
- Dropped Frames%
- Share of the expected screen frames of the moving displays that the browser skipped.
- Over 0.05 is flagged for review
- Stopped Early0/1
- 1 when the participant stopped the test before the end, by Esc, the Stop button, leaving full screen or the button between displays.
- Flagged for review; the scores cover the displays shown to the end
- Completed Displaystrials
- Displays shown to the end in the scored run.
- Fewer than planned is flagged for review
- Planned Displaystrials
- Displays the run set out to show.
- Informational
Use and evidence
87 papers from 2021 to 2025 name this task in their title or abstract, down 36% compared with 2016 to 2020. That ranks it 314 of 711 test families in our census. See the counts for every test.
Show the numbers
| Year | Papers |
|---|---|
| 2025 | 18 |
| 2024 | 10 |
| 2023 | 22 |
| 2022 | 11 |
| 2021 | 26 |
| 2020 | 19 |
| 2019 | 29 |
| 2018 | 28 |
| 2017 | 29 |
| 2016 | 31 |
| 2015 | 37 |
| 2014 | 37 |
| 2013 | 29 |
| 2012 | 43 |
| 2011 | 36 |
| 2010 | 34 |
| 2009 | 20 |
| 2008 | 26 |
| 2007 | 11 |
| 2006 | 15 |
| 2005 | 8 |
| 2004 | 19 |
| 2003 | 22 |
| 2002 | 16 |
| 2001 | 18 |
| 2000 | 18 |
Use grade D
30 to 99 papers from 2021 to 2025.
Evidence grade C
At least 2 test-retest papers, 30 reliability or validity papers or 3 registered clinical studies.
- Papers on test-retest reliability
- 1
- Papers on reliability or validity
- 9
- Registered clinical studies using it as an outcome
- 4
Measured on ConductCognition
Pooled across the studies that feed our platform norms, by device group. A figure needs 50 or more people.
No pooled figure yet.
Note on the counts: includes virtual reality and motion sickness studies.
How the grades work
Use: A is 1,000 or more papers from 2021 to 2025, B 300 to 999, C 100 to 299, D 30 to 99 and E fewer than 30. Evidence: A means at least 25 papers report its test-retest reliability and at least 25 registered clinical studies use it as an outcome; B, at least 8 test-retest papers, and either 5 registered clinical studies or 150 reliability or validity papers; C, at least 2 test-retest papers, 30 reliability or validity papers or 3 registered clinical studies; D, little published measurement evidence found. The counts measure use. They include every paper that names the task in its title or abstract. Grades describe the published research on this task, not ConductCognition's version of it.
Source: ConductCognition test census 0.58.0, counted 12 November 2026 from OpenAlex and ClinicalTrials.gov.
Task design
The trial sequence as the test runs in ConductCognition.
- Display
- White dots on black fill the screen, with a red dot at the center to look at: a cloud of dots at depths of 1 to 12 units, one dot for each 300 square pixels of the screen. Dots grow from 2 to 6 px as they come nearer and fade in and out with depth, so nothing flickers.
- Conditions
- Expanding flow at 2 and 5 depth units per second, rotating flow at 25 and 50 degrees per second, and still dots as a control. Each display shows the dots still for 1,000 ms, then moving for 30 s, easing in over the first 1,000 ms.
- Displays
- Each repeat shows the five conditions once in a new order: 2 repeats (standard; 1 to 4) give 10 displays. Between displays the participant rests as long as they like.
- Answer
- The space bar once, as soon as the participant feels they are moving; then a rating of how strongly, from 1 (not at all) to 7 (very strongly).
- Practice
- One 15 s display of fast expanding flow, followed by the time of the press or a note that there was none.
- Comfort
- A warning about motion discomfort comes before the test. Esc, a Stop button in the corner, leaving full screen or a button between displays ends the test at any time.
- Scores
- The strength rating and the time to the first press for each flow and speed, the share of displays with a press, and the still dots' rating and presses as a baseline.
The flow is drawn in code and the scores are times and ratings on the participant's own screen, so no calibration is needed. A stronger or quicker feeling of moving is not a better score. The scores support research and do not diagnose.
Quality checks
Each session is marked valid, needs review or invalid, with the reason, before you see its scores.
Scored rows: self_motion_test from the run with the most displays, ties going to the latest run, each with the rating row of the same display; displays stopped or cut short leave the scores. A moving display has no right answer, so accuracy is not judged against chance, and a display with no press is a valid report of no feeling of moving. A test the participant stopped, a short run, poor display timing, or still dots pressed as often and rated as strongly as moving ones is flagged for review. Presses are timed from the start of motion, and responses under 100 ms follow the timed-test rule.
Why these rules
There is no correct option to compare with chance, so accuracy is not judged against chance. Vection takes seconds to build after motion starts (Brandt, Dichgans and Koenig, 1973), so a press within 100 ms of the start cannot report it. Self-reports can follow what a person expects rather than what they feel (Palmisano, Allison, Schira and Barry, 2015), so the still dots are a control: presses and ratings no lower for them than for flow are flagged. Participants may stop at any time, and a stopped test is flagged, not invalid. A hidden tab stops the flow, so a percentile is withheld after one.
No percentile. Scores and quality flags only.
Running this test
Settings you can change
| Setting | Standard | Allowed |
|---|---|---|
| Displays of each condition | 2 | 1 to 4 |
Yearly plans can change settings within these limits. Free and pay-as-you-go studies use the standard settings.
Need a setting this test does not have?
Devices and languages
- Timed test: participants need a desktop or laptop with a mouse or trackpad. Participant devices
- Languages: English, Spanish, French, German, Italian, Portuguese (Brazil), Chinese (Simplified) and Japanese.
- Available on: Every plan, including the free plan.
- No percentile. Scores and quality flags only. How norms work
- Recruiting online? See the setup guides for Prolific, Sona Systems, CloudResearch Connect and Qualtrics.
Cite and describe
Participants completed the Self-Motion Task in a web browser (ConductCognition task version 1.0.0, scoring version 1.0.0; Brandt, Dichgans and Koenig, 1973; Palmisano and Gillam, 1998; Palmisano, Allison, Schira and Barry, 2015), with the standard settings (displays of each condition: 2). The main score was strength of self-motion (mean rating of how strongly the participant felt they were moving, 1 (not at all) to 7 (very strongly), over the moving displays shown to the end).
ConductCognition versions: task version 1.0.0, scoring version 1.0.0. Every export records the versions each session used, for a methods section.
- Brandt, T., Dichgans, J., & Koenig, E. (1973). Differential effects of central versus peripheral vision on egocentric and exocentric motion perception. Experimental Brain Research, 16(5), 476-491. https://doi.org/10.1007/BF00234474Vection from a moving surround: it begins after a few seconds and grows, with latencies that do not depend on the speed.
- Palmisano, S., & Gillam, B. (1998). Stimulus eccentricity and spatial frequency interact to determine circular vection. Perception, 27(9), 1067-1077. https://doi.org/10.1068/p271067How strong circular vection is depends on the pattern of the flow and where it falls in view.
- Palmisano, S., Allison, R. S., Schira, M. M., & Barry, R. J. (2015). Future challenges for vection research: definitions, functional significance, measures, and neural bases. Frontiers in Psychology, 6, 193. https://doi.org/10.3389/fpsyg.2015.00193Review of how vection is measured: onset times from button presses and strength ratings.
Source papers
- Brandt T, Dichgans J, Koenig E (1973). Differential effects of central versus peripheral vision on egocentric and exocentric motion perception. Experimental Brain Research, 16(5):476-491.Paradigm source, Adults
Questions
How long does the Self-Motion Task take?
About 8 to 10 minutes, as listed in the test library.
What device does a participant need?
Timed test: participants need a desktop or laptop with a mouse or trackpad. The browser must be Chrome, Edge, Firefox or Safari.
What scores does it produce?
Strength of Self-Motion, Time to Self-Motion, Displays with Self-Motion, Strength, Slow Expanding Flow, Strength, Fast Expanding Flow, Strength, Slow Rotating Flow, Strength, Fast Rotating Flow, Time to Self-Motion, Slow Expanding Flow, Time to Self-Motion, Fast Expanding Flow, Time to Self-Motion, Slow Rotating Flow, Time to Self-Motion, Fast Rotating Flow, Strength, Still Dots, Presses for Still Dots, Early Presses, Anticipations, Frame Interval, Dropped Frames, Stopped Early, Completed Displays and Planned Displays. Each session is also marked valid, needs review or invalid, with the reason.
How widely is the Self-Motion Task used in research?
87 papers from 2021 to 2025 name it in their title or abstract, down 36% compared with 2016 to 2020. That ranks it 314 of 711 test families in the ConductCognition test census (use grade D). Source: ConductCognition test census 0.58.0, counted 12 November 2026 from OpenAlex and ClinicalTrials.gov.
How much reliability evidence does the Self-Motion Task have?
In the published research, 1 paper reports its test-retest reliability and 4 registered clinical studies use it as an outcome (evidence grade C in the ConductCognition test census).
Does it report a percentile?
No. Scores and quality flags only.
Which settings can a researcher change?
Displays of each condition (1 to 4). Settings can be changed on yearly plans; free and pay-as-you-go studies use the standard settings.
Which languages can participants use?
Participants can take this test in English, Spanish, French, German, Italian, Portuguese (Brazil), Chinese (Simplified) and Japanese. English is on every plan, and the other languages come with yearly plans. Have a native speaker read the machine-translated text before launch.
Is this a clinical test?
No. ConductCognition is for research use only. It runs, scores and exports the test; clinical interpretation is outside the platform.
Every test: the full test list.
Run this test in your next study
Start free with 10 free participants on any test, then use participant credits or a yearly plan.