Attention
Alert Sounds Task
Also called: earcons, auditory icons, earcon and auditory icon learning, alert sound identification, auditory warnings, perceived urgency, urgency mapping, auditory displays
Measure how quickly listeners learn what alert sounds mean: six sounds, tone patterns and sound-like icons, are identified over blocks with feedback through headphones, then warning sounds are rated for urgency as their speed, pitch and harmonics change.
6-8 minUntimed
Free to start: 10 free participants per account, then $0.99 per participant for academic research, or any yearly plan. Try it here first, with no account.
- Papers, 2021 to 2025
- 71
- Evidence grade
- D
- Registered clinical studies
- 0
What it measures
Measures how quickly people learn what short alert sounds mean and how urgent warning sounds seem. Participants learn six alert sounds through headphones, three tone patterns and three sound-like icons, identify each one over several blocks with feedback, then rate the urgency of warning sounds that vary in speed, pitch and harmonics.
Constructs
- Auditory learning
- Sound identification
- Perceived urgency
Research uses
- Auditory display research
- Alarm and warning design research
- Human factors research
How the paradigm works
Alert sounds carry meaning in two ways. Auditory icons are caricatures of everyday sounds that stand for what they mean (Gaver, 1986); earcons are abstract motives of a few pitches in a rhythm, whose meanings are learned (Blattner, Sumikawa and Greenberg, 1989). Warning research adds how urgent a sound seems: its speed, fundamental frequency and harmonic series change perceived urgency (Edworthy, Loxley and Dennis, 1991; Hellier, Edworthy and Dennis, 1993).
More about the paradigm
Set a comfortable volume and take the 6-trial headphone check. A failed check stops the task by default; researchers can continue with a quality flag.
6 meanings: someone at the door, file deleted, file sent, payment received, time is up and battery low. Each session hears three as tone patterns, motives of two to four notes, and three as sound-like icons that resemble their meaning: knocks, crackling paper, a rush of air, metallic pings, a ringing bell and a falling buzz. The session's seed decides which three are icons, so across a study every meaning is learned both ways.
Each sound plays once with its meaning. Then each block plays all six in a new order: press Play, listen once and choose the meaning from six buttons, with no time limit. The right meaning shows for 1,500 ms after every answer. 4 blocks (24 trials) by default, 2 to 6 as a setting.
Six pulses of 100 ms, each four partials, harmonic or inharmonic, with 300, 150 or 50 ms of silence between pulses and a fundamental of 250, 500 or 1,000 Hz: 18 sounds, each rated once from 1 (not urgent) to 7 (extremely urgent) after one practice rating. Every sound plays 14 dB below the volume-setting tone, every pulse at the same level.
The primary score is identification accuracy over all blocks. Accuracy by block and the gain from the first block to the last show learning; accuracy and the time of right answers for tone patterns and for sound-like icons compare the two kinds. Urgency is reported by speed, pitch and harmonics, with the fast minus slow, high minus low and inharmonic minus harmonic differences. Answers under 100 ms from the buttons opening leave scores.
Scores
- Identification accuracy%
- Share of usable identification answers that named the sound's meaning, over every learning block.
- Higher means the alert sounds were learned better; descriptive
- Accuracy by block%
- Share of usable answers that were right in each learning block, keyed by the block.
- Descriptive; rising values show learning
- Learning gain%
- Accuracy in the last learning block minus accuracy in the first.
- Positive means accuracy rose with practice; descriptive
- Sound-like icon accuracy%
- Share of usable answers that were right for the three sounds that resemble their meaning.
- Descriptive
- Tone pattern accuracy%
- Share of usable answers that were right for the three tone patterns.
- Descriptive
- Icon minus tone pattern accuracy%
- Sound-like icon accuracy minus tone pattern accuracy.
- Positive means the icons were identified more accurately; descriptive
- Icon answer timems
- Median time of right answers for sound-like icons, from the answer buttons opening.
- Informational
- Tone pattern answer timems
- Median time of right answers for tone patterns, from the answer buttons opening.
- Informational
- Urgency by speedscore
- Mean urgency rating of the slow, medium and fast warning sounds, keyed by speed.
- Descriptive; no better direction
- Urgency by pitchscore
- Mean urgency rating at fundamentals of 250, 500 and 1,000 Hz, keyed low, medium and high.
- Descriptive; no better direction
- Speed effectscore
- Mean urgency of the fast warning sounds minus the slow ones.
- Positive means faster sounds were rated more urgent; descriptive
- Pitch effectscore
- Mean urgency at a fundamental of 1,000 Hz minus 250 Hz.
- Positive means higher sounds were rated more urgent; descriptive
- Inharmonic effectscore
- Mean urgency of the inharmonic warning sounds minus the harmonic ones.
- Positive means inharmonic sounds were rated more urgent; descriptive
- Mean urgencyscore
- Mean of all usable urgency ratings.
- Descriptive; no better direction
- Median answer timems
- Median time of usable identification answers after the answer buttons open.
- Informational
- Anticipationscount
- Answers and ratings under 100 ms, excluded from scores.
- Informational
- Completed trialstrials
- Identification answers and urgency ratings in the selected run.
- Informational
- Planned trialstrials
- Identification trials and urgency ratings planned for the selected run.
- Informational
- Headphone check passedscore
- 1 for a passed equipment check, 0 for a failed check.
- Informational
- Headphone check correctcount
- Correct equipment-check responses out of six.
- Informational
- Reported output delayms
- Output delay reported by the browser, or empty when unavailable.
- Informational
Use and evidence
71 papers from 2021 to 2025 name this task in their title or abstract, up 13% compared with 2016 to 2020. That ranks it 360 of 711 test families in our census. See the counts for every test.
Show the numbers
| Year | Papers |
|---|---|
| 2025 | 13 |
| 2024 | 10 |
| 2023 | 10 |
| 2022 | 23 |
| 2021 | 15 |
| 2020 | 7 |
| 2019 | 16 |
| 2018 | 17 |
| 2017 | 12 |
| 2016 | 11 |
| 2015 | 10 |
| 2014 | 9 |
| 2013 | 10 |
| 2012 | 6 |
| 2011 | 12 |
| 2010 | 14 |
| 2009 | 15 |
| 2008 | 5 |
| 2007 | 13 |
| 2006 | 11 |
| 2005 | 8 |
| 2004 | 8 |
| 2003 | 8 |
| 2002 | 2 |
| 2001 | 4 |
| 2000 | 6 |
Use grade D
30 to 99 papers from 2021 to 2025.
Evidence grade D
Little published measurement evidence found.
- Papers on test-retest reliability
- 0
- Papers on reliability or validity
- 11
- Registered clinical studies using it as an outcome
- 0
Measured on ConductCognition
Pooled across the studies that feed our platform norms, by device group. A figure needs 50 or more people.
No pooled figure yet.
Note on the counts: includes interface and alarm design studies.
How the grades work
Use: A is 1,000 or more papers from 2021 to 2025, B 300 to 999, C 100 to 299, D 30 to 99 and E fewer than 30. Evidence: A means at least 25 papers report its test-retest reliability and at least 25 registered clinical studies use it as an outcome; B, at least 8 test-retest papers, and either 5 registered clinical studies or 150 reliability or validity papers; C, at least 2 test-retest papers, 30 reliability or validity papers or 3 registered clinical studies; D, little published measurement evidence found. The counts measure use. They include every paper that names the task in its title or abstract. Grades describe the published research on this task, not ConductCognition's version of it.
Source: ConductCognition test census 0.58.0, counted 14 November 2026 from OpenAlex and ClinicalTrials.gov.
Task design
The trial sequence as the test runs in ConductCognition.
- Sound setup
- Set a comfortable volume and take the 6-trial headphone check. A failed check stops the task by default; researchers can continue with a quality flag.
- Alert sounds
- 6 meanings: someone at the door, file deleted, file sent, payment received, time is up and battery low. Each session hears three as tone patterns, motives of two to four notes, and three as sound-like icons that resemble their meaning: knocks, crackling paper, a rush of air, metallic pings, a ringing bell and a falling buzz. The session's seed decides which three are icons, so across a study every meaning is learned both ways.
- Learning
- Each sound plays once with its meaning. Then each block plays all six in a new order: press Play, listen once and choose the meaning from six buttons, with no time limit. The right meaning shows for 1,500 ms after every answer. 4 blocks (24 trials) by default, 2 to 6 as a setting.
- Warning sounds
- Six pulses of 100 ms, each four partials, harmonic or inharmonic, with 300, 150 or 50 ms of silence between pulses and a fundamental of 250, 500 or 1,000 Hz: 18 sounds, each rated once from 1 (not urgent) to 7 (extremely urgent) after one practice rating. Every sound plays 14 dB below the volume-setting tone, every pulse at the same level.
- Scores
- The primary score is identification accuracy over all blocks. Accuracy by block and the gain from the first block to the last show learning; accuracy and the time of right answers for tone patterns and for sound-like icons compare the two kinds. Urgency is reported by speed, pitch and harmonics, with the fast minus slow, high minus low and inharmonic minus harmonic differences. Answers under 100 ms from the buttons opening leave scores.
Auditory icons are caricatures of everyday sounds that stand for what they mean (Gaver, 1986); earcons are abstract motives whose meanings are learned (Blattner, Sumikawa and Greenberg, 1989). In warning design, a sound's speed, fundamental frequency and harmonic series change how urgent it sounds (Edworthy, Loxley and Dennis, 1991; Hellier, Edworthy and Dennis, 1993). Our synthetic sounds follow both lines of work, and the scores describe learning and ratings within this task, with no percentile. Headphones, normal hearing and a comfortable volume are required; levels are relative rather than calibrated. Results do not assess hearing.
Quality checks
Each session is marked valid, needs review or invalid, with the reason, before you see its scores.
Scored rows: alert_sounds_identify from the selected run, each answer one of six meanings after the sound has played, graded from the button and the row's button order; the urgency ratings have no correct answer. Below chance (1 in 6) invalidates and not above chance is flagged; one meaning on 90% of answers invalidates when accuracy is not above chance; answers under 100 ms invalidate when at least half. One urgency rating throughout, a short run and a failed headphone check are flagged for review, and a stopped check leaves no results.
Why these rules
Accuracy significantly below chance (one-sided exact test, p < .05) cannot come from guessing; it means the response mapping was reversed or the task was not followed (Slick, Sherman and Iverson 1999 treat below-chance forced-choice performance as definite response bias). Chance-level accuracy can be a real result in impaired participants, so it is only flagged. One option on at least 90% of answered trials, when the correct options are balanced and accuracy is not above chance, means the answers did not depend on the items (the task counterpart of long-string responding in surveys; Curran 2016). The answers open once the sound has played and have no time limit, so an answer under 100 ms was pressed before they opened, and only a session made mostly of such answers is invalid. Early blocks can sit near chance while the meanings are being learned, which is why only accuracy below chance over all blocks invalidates. A failed headphone check that stopped the test leaves no trials to score (Woods, Siegel, Traer and McDermott, 2017).
No percentile. Scores and quality flags only.
Running this test
Settings you can change
| Setting | Standard | Allowed |
|---|---|---|
| When the headphone check fails | Stop the test | Stop the test, Continue the test |
| Learning blocks | 4 | 2 to 6 |
Yearly plans can change settings within these limits. Free and pay-as-you-go studies use the standard settings.
Need a setting this test does not have?
Devices and languages
- Untimed test: runs on desktops, laptops, tablets and phones. Needs headphones. Participant devices
- Languages: English, Spanish, French, German, Italian, Portuguese (Brazil), Chinese (Simplified) and Japanese.
- Available on: Every plan, including the free plan.
- No percentile. Scores and quality flags only. How norms work
- Recruiting online? See the setup guides for Prolific, Sona Systems, CloudResearch Connect and Qualtrics.
Cite and describe
Participants completed the Alert Sounds Task in a web browser (ConductCognition task version 1.0.0, scoring version 1.0.0; Gaver, 1986; Blattner, Sumikawa and Greenberg, 1989; Edworthy, Loxley and Dennis, 1991; Hellier, Edworthy and Dennis, 1993), with the standard settings (when the headphone check fails: Stop the test; learning blocks: 4). The main score was identification accuracy (share of usable identification answers that named the sound's meaning, over every learning block).
ConductCognition versions: task version 1.0.0, scoring version 1.0.0. Every export records the versions each session used, for a methods section.
- Gaver, W. W. (1986). Auditory icons: Using sound in computer interfaces. Human-Computer Interaction, 2(2), 167-177. https://doi.org/10.1207/s15327051hci0202_3Auditory icons: caricatures of everyday sounds that stand for the objects and events they represent.
- Blattner, M. M., Sumikawa, D. A., & Greenberg, R. M. (1989). Earcons and icons: Their structure and common design principles. Human-Computer Interaction, 4(1), 11-44. https://doi.org/10.1207/s15327051hci0401_1Earcons built from motives, short rhythmic sequences of pitches, and how they are learned.
- Edworthy, J., Loxley, S., & Dennis, I. (1991). Improving auditory warning design: Relationship between warning sound parameters and perceived urgency. Human Factors, 33(2), 205-231. https://doi.org/10.1177/001872089103300206Warning sound parameters, among them speed, fundamental frequency and harmonic series, that change perceived urgency.
- Hellier, E. J., Edworthy, J., & Dennis, I. (1993). Improving auditory warning design: Quantifying and predicting the effects of different warning parameters on perceived urgency. Human Factors, 35(4), 693-706. https://doi.org/10.1177/001872089303500408Perceived urgency scaled across speed, fundamental frequency, repetition units and inharmonicity.
- Woods, K. J. P., Siegel, M. H., Traer, J., & McDermott, J. H. (2017). Headphone screening to facilitate web-based auditory experiments. Attention, Perception, & Psychophysics, 79(7), 2064-2072. https://doi.org/10.3758/s13414-017-1361-2The shared headphone check.
Source papers
- Edworthy, J., Loxley, S., & Dennis, I. (1991). Improving auditory warning design: Relationship between warning sound parameters and perceived urgency. Human Factors, 33(2), 205-231.Paradigm source, Adults
Questions
How long does the Alert Sounds Task take?
About 6 to 8 minutes, as listed in the test library.
What device does a participant need?
Untimed test: runs on desktops, laptops, tablets and phones. Needs headphones. The browser must be Chrome, Edge, Firefox or Safari.
What scores does it produce?
Identification accuracy, Accuracy by block, Learning gain, Sound-like icon accuracy, Tone pattern accuracy, Icon minus tone pattern accuracy, Icon answer time, Tone pattern answer time, Urgency by speed, Urgency by pitch, Speed effect, Pitch effect, Inharmonic effect, Mean urgency, Median answer time, Anticipations, Completed trials, Planned trials, Headphone check passed, Headphone check correct and Reported output delay. Each session is also marked valid, needs review or invalid, with the reason.
How widely is the Alert Sounds Task used in research?
71 papers from 2021 to 2025 name it in their title or abstract, up 13% compared with 2016 to 2020. That ranks it 360 of 711 test families in the ConductCognition test census (use grade D). Source: ConductCognition test census 0.58.0, counted 14 November 2026 from OpenAlex and ClinicalTrials.gov.
How much reliability evidence does the Alert Sounds Task have?
In the published research, 0 papers report its test-retest reliability and 0 registered clinical studies use it as an outcome (evidence grade D in the ConductCognition test census).
Does it report a percentile?
No. Scores and quality flags only.
Which settings can a researcher change?
When the headphone check fails (Stop the test, Continue the test) and learning blocks (2 to 6). Settings can be changed on yearly plans; free and pay-as-you-go studies use the standard settings.
Which languages can participants use?
Participants can take this test in English, Spanish, French, German, Italian, Portuguese (Brazil), Chinese (Simplified) and Japanese. English is on every plan, and the other languages come with yearly plans. Have a native speaker read the machine-translated text before launch.
Is this a clinical test?
No. ConductCognition is for research use only. It runs, scores and exports the test; clinical interpretation is outside the platform.
Every test: the full test list.
Run this test in your next study
Start free with 10 free participants on any test, then use participant credits or a yearly plan.